Hanna HI83308-02 Multiparameter Photometer and pH Meter for Water Treatment (230V)
Up to 23 pre-programmed methods
Cal Check System
Direct measurement in Absorbance
The HI83308-02 model comes with 4 measuring cuvettes with lids, a cuvette cleaning cloth, a USB to micro USB cable connector, a power adapter, and an instruction manual.
It is one of the most advanced photometers available with an innovative optical design that uses a reference detector and focusing lenses to eliminate errors from changes in the light source and imperfections in the glass cuvette.
To save valuable laboratory space, the HI83308 functions as a professional pH meter with its digital pH input.
temperature.
Photometer and pH Mode
With more than 60 pre-programmed methods, the user can easily access the method and range they need. Furthermore, the HI833xx series, considering the importance of reaction time in photometry, has a timer to minimize differences between users (reproducibility).
CAL Check
This HI83xxx series features the same system developed by HANNA, allowing verification of different absorbances using HANNA certified standards. The instrument is also capable of measuring absorbance.
Consult the standards for each photometer in the 833 Series.
Optical Improvement
Greater linearity/accuracy at high absorbances or low ranges and faster analysis thanks to the reference detector. In addition, the focusing lens reduces friction and cuvette positioning errors.
On instruments programmed for COD parameter measurement, the instrument includes a 16mm cuvette adapter. For the remaining parameters, it uses a 25mm cuvette for improved measurement accuracy.
Absorbance Mode
All instruments have the capability to display the absorbance value. This allows the user to view matrix stability or manually create their own curves from their own standards using user methods and the instrument's available wavelengths.
Data Logging
This series stores up to 1000 records, including pH measurements.
Simply pressing the Log button will record the measurement, allowing you to name the user and sample, in addition to basic GLP data such as date, time, and CAL Check values.
pH Measurement
The HI833xx series can be connected to an edge® series digital pH electrode to convert the device into a pH meter.
All these electrodes have an integrated temperature sensor, enabling automatic temperature compensation. Furthermore, as they are intelligent electrodes, they can memorize the last calibration: date, values, offset, slope, etc. When connected to the device, they transfer all this information.